Solinst Model 3001 Levelogger 5 LTC
User-Friendly Operation
Software Calibration and Data Wizards guide you through conductivity calibration and barometric compensation, ensuring accurate data sets. The Data Wizard also converts conductivity readings to Specific Conductance (@ 25ºC).
Levelogger Software allows you to easily program your preferences, download data,and display data in a graph or table format or export to other programs. Real Time View allows immediate viewing of live water level, conductivity, and temperature readings.
Leveloggers are easy to deploy; install with direct read cables or wireline/cord suspension. The Levelogger 5 LTC is SDI-12 compatible using the Solinst SDI-12 Interface Cable.
Download data in the field using the new Field Reader 5, DataGrabber 5 USB data transfer device, or through Bluetooth® using the Levelogger 5 App Interface and your smart device. Integrate the Levelogger 5 LTC with Solinst Telemetry Systems, which use the latest wireless technologies.
Levelogger 5 LTC Applications
- Salt water intrusion and soil salination monitoring
- Plume remediation monitoring and studies
- Leachate monitoring at landfills, mine tailings, waste disposal storage sites, and more
- Agricultural and stormwater runoff monitoring
- Create a historical database for potable water supply monitoring
- Tracer tests
Level Sensor: | Piezoresistive Silicon with Hastelloy Sensor |
Ranges: | 5, 10, 20, 30, 100, and 200 m |
Accuracy: | ±0.05% FS |
Resolution: | 0.001% FS to 0.0006% FS |
Units of Measure: | cm, m, ft, psi, kPa, bar (ºC, ºF) |
Normalization: | Automatic Temperature Compensation |
Temp Comp. Range: | 0ºC to 50ºC |
Temperature Sensor: | Platinum Resistance Temperature Detector (RTD) |
Accuracy: | ±0.05ºC |
Resolution: | 0.003ºC |
Conductivity Sensor: | 4-Electrode Platinum |
Full Range: | 0 – 100,000 μS/cm |
Calibrated Range: | 50 – 80,000 μS/cm |
Accuracy: | ±1%: 5,000 μS/cm – 80,000 μS/cm; greater of ±2% or 15 μS/cm: 50 μS/cm –5,000 μS/cm |
Resolution: | ±0.1 μS/cm |
Temp Comp. Range: | 0ºC – 50ºC |
Normalization: | Specific Conductance @ 25˚C |
Battery Life: | 8 Years (1 reading every 5 minutes) |
Clock Accuracy (typical): | ±1 minute/year (-20ºC to 80ºC) |
Operating Temperature: | -20ºC to 80ºC |
Maximum Readings: | 100,000 sets of readings |
Memory: | Slate or Continuous |
Communication: | Optical high-speed: 57,600 bps with USB |
Size: | 22 mm x 208 mm (7/8" x 8.2") |
Weight: | 197 grams (6.95 oz) |
Corrosion Resistance: | Baked-on coating using polymerization |
Wetted Materials: | Platinum, Delrin®, Viton®, 316L Stainless Steel, Hastelloy, Regulator approved PFAS-free PTFE (inside and out) |
Sampling Mode: | Linear, Event & User-Selectable with Repeat Mode, Future Start, Future Stop, Real-Time View |
Measurement Rates: | 2 seconds to 99 hours |
Barometric Compensation: | Software Wizard and Barologger 5 |