The Solinst Levelogger 5 is an all-in-one water level datalogger engineered for long-term reliability and precision. Designed for seamless performance, it features a robust 10-year lithium battery and utilizes advanced infrared technology for wireless data transfer. Whether your project requires permanent or temporary deployment, the Levelogger 5 offers versatile installation options, including Direct Read Cables, stainless steel wireline, or high-strength Kevlar cord.
Key Performance Specs:
The "M" Rule for Simple Ordering
The model number indicates the Maximum Submergence Depth in meters. Use the table below to find the right fit for your application:
| Model | Max Submergence (Meters) | Max Submergence (Feet) | Best For... |
| M5 | 5 Meters | ~16.4 Feet | Shallow wells, streams, and wetlands. |
| M10 | 10 Meters | ~32.8 Feet | Standard groundwater monitoring. |
| M20 | 20 Meters | ~65.6 Feet | Mid-range boreholes and tidal areas. |
| M30 | 30 Meters | ~98.4 Feet | Deep wells and reservoir monitoring. |
| M100 | 100 Meters | ~328.1 Feet | Deep aquifer studies. |
| M200 | 200 Meters | ~656.2 Feet | High-pressure deep-well applications. |
The 3001 Levelogger 5 Barometric Sensor is designed to allow seamless integration with absolute pressure sensors to correct for barometric pressure - ensuring precise correction of water level data. researchers committed to precise data collection in their monitoring efforts.
| Level Sensor: | Piezoresistive Silicon with Hastelloy Sensor |
| Accuracy: | ± 0.05% FS (Barologger 5: ± 0.05 kPa) |
| Stability of Readings: | Superior, low noise |
| Resolution: | 0.002% FS to 0.0006% FS |
| Units of Measure: | m, cm, ft., psi, kPa, bar, ºC. ºF (Barologger 5: psi, kPa, mbar, ºC, ºF) |
| Normalization: | Automatic Temp Compensation |
| Temp Comp. Range: | 0º to 50ºC (Barologger 5: -10 to +50ºC) |
| Temperature Sensor: | Platinum Resistance Temperature Detector |
| Temp. Senosr Accuracy: | ± 0.05ºC |
| Temp Sensor Resolution: | 0.003°C |
| Battery Life: | 10 Years – based on 1 reading/minute |
| Operating Temperature: | - 20ºC to 80ºC |
| Clock Accuracy (typical): | ± 1 minute/year (- 20ºC to 80ºC) |
| Memory Modes: | Continuous or Slate |
| Maximum # Readings: | 150,000 sets of readings |
| Communication: | Optical high-speed: USB, SDI-12 57,600 bps with USB |
| Size: | 22 mm x 160 mm (7/8" x 6.3") |
| Weight: | 166 grams (5.9 oz) |
| Corrosion Resistance: | Baked-on coating using polymerization technology (inside and out) |
| Other Wetted Materials: | Delrin®, Viton®, 316L stainless steel, Hastelloy, PFAS-free PTFE coating |
| Sampling Mode: | Linear, Event & User-Selectable with Repeat Mode, Future Start, Future Stop, Real-Time View |
| Measurement Rates: | 1/8 sec to 99 hrs |
| Barometric Compensation: | Software Wizard and one Barologger 5 in local area (approx. 30 km/20 miles radius) |