ENVIRONMENTAL SAMPLING EQUIPMENT

Ion Science Titan 2 wall-mounted benzene gas monitor

Ion Science Titan 2 — Wall-Mounted Continuous Benzene-Specific Gas Monitor

The Ion Science Titan 2 is a wall-mounted, continuous, benzene-specific gas monitor — not a total-VOC detector reporting benzene by inference. It reports benzene from 0.02 ppm (20 ppb) to 20 ppm, sampling once per minute, and is selective for benzene within a typical petrochemical matrix.

Selectivity comes from the MiniPID T2 10.0 eV sensor combined with sample conditioning that removes interfering gases before measurement. The enclosure is internally heated for temperature stability, IP65 rated, and certified for ATEX zones — so readings hold up in dusty or humid conditions where an unheated instrument would drift.

The design is deliberately modular: the Ex d case is installed and wired in advance, and the detector module is removed and replaced at service time. Downtime is a module swap, not a re-installation.

Servicing

Titan 2 has a defined six-month minimum service period covering the PID lamp, electrode stack, inline filter, VRV restrictor and hydrophobic and carbon filters, with the AirSep filter added at twelve months. MiniPID sensors, electrode stacks, lamps, cleaning kits and accessory kits are stocked in Titan & Titan 2 Spares & Accessories. Calibration gas is listed under Calibration Gas.

Browse all Ion Science Parts and Accessories, or see the full instrument range in Ion Science. For total VOC rather than benzene-specific monitoring, see the Falco 2.

  • Benzene-specific measurement — selective within a petrochemical matrix rather than reporting total VOC and calling it benzene
  • Detects to 20 ppb — 0.02 ppm lower limit with 10 ppb resolution, sampled every minute
  • Modular servicing — install the Ex d case once, then swap the detector module at service, minimizing downtime
  • Internally heated for stability — IP65 rated, so dust and humidity do not move the baseline
  • Integrates with your controller — isolated 4-20 mA, RS485 Modbus (ASCII or RTU) and two isolated voltage-free relays
  • Six months of on-board data — stored to internal MMC and downloadable over micro USB for analysis
  • Refinery fenceline monitoring — continuous benzene measurement at site boundaries
  • Petrochemical process areas — fixed-point monitoring where benzene is the regulated compound
  • Vapor recovery and purification units — verifying that abatement equipment is performing
  • Tank farms and loading racks — monitoring around transfer operations
  • Industrial hygiene programs — continuous area monitoring against occupational benzene limits
  • Regulatory compliance reporting — six months of on-board data supporting emissions records

Regular price$26,883.10
/